Appendix 3 Modbus Data Address Table I - Excell EX2005 User Manual

Table of Contents

Advertisement

EXCELL PRECISION CO., LTD

Appendix 3 MODBUS Data Address Table I

Data Register
Function Code 03 (Read
Modbus
SCALE
40000 ~ 40001
As display value
40002 ~ 40003
Gross weight
40004 ~ 40005
Net weight
40006 ~ 40007
Tare weight
Gross weight
40008 ~ 40009
hold value
Net weight
40010 ~ 40011
hold value
Weight final
40012 ~ 40013
value
40014 ~ 40015
Unit weight
Percentage
40016 ~ 40017
value
40018 ~ 40019
Totalised value
40020 ~ 40021
Totalised times
Totalised times
40022 ~ 40023
of HI value
Totalised times
40024 ~ 40025
of Lo value
Totalised times
40026 ~ 40027
of OK value
Function Code 06 and 16 (Write)
41000 ~ 41001
Pre-tare value
41002 ~ 41003
Zero Band value
41004 ~ 41005
Target value
41006 ~ 41007
SP1 value
41008 ~ 41009
SP2 value
41010 ~ 41011
SP3 value
41012 ~ 41013
LO_LO value
41014 ~ 41015
LO value
41016 ~ 41017
HI_HI value
41018 ~ 41019
HI value
41020 ~ 41021
Under value
41022 ~ 41023
Over value
Peak value
41024 ~ 41025
setting
Batch Finish
41026 ~ 41027
delay time
SPAN calibration
41100 ~ 41101
value
04011210
Bit I/O
)
Function Code 01 (Read)
Modbus
SCALE Output
00000
Stable status
00001
Zero status
00002
Gross
00003
00050
Zero Band
00051
Sp1
00052
Sp2
00053
Sp3
00054
Batch Finish
00055
Under
00056
Over
00057
Unloading
00058
Hi-Hi
00059
00060
00061
00062
Lo-Lo
00063
Peak ready
00064
Running
00065
ZERO calibration
00066
SPAN calibration
00067
Calibrate ERR0
00068
Calibrate ERR2
00069
Calibrate ERR6
70
Function Code 05 and 15 (Write)
Modbus
01000
01001
01002
Net
01003
01004
01005
01006
01007
01008 ~ 01027
01049
01050
01051
01052
Hi
01053
Go
01054
Lo
01055
01056
01057
01058
01059
01060
Bit I/O
SCALE Input
Zero
Clear zero compensation
Tare
Clear Tare
Clear Pre-tare
Display the gross weight on
main display
Display the net weight on
main display
Enter/Exit the function
mode
Switch unit
st
th
from the 1
to 20
Switch the operation modes
Totalised the current net
weight and add 1 to the
totalised times
Deduct the last totalised
value and deduct 1 to the
totalised times
Clear the totalised value
and times
Running
Stop
Discharge starts
Hold mode ON/OFF
Release "Hold value"
Output judgement
ZERO calibration
SPAN calibration
ZSME400000003

Advertisement

Table of Contents
loading

Table of Contents