EXCELL PRECISION CO., LTD
Item
Function
RS1- 01
Transmit format
RS2- 01
RS1- 02
Transmit mode
RS2- 02
RS1- 03
Transmit speed
RS2- 03
Parity
Bit length
Stop Bit
RS1- 04
RS2- 04
Parity
Bit length
Stop Bit
RS1- 05
Transmit times
RS2- 05
RS1- 06
Transmission
RS2- 06
conditions
RS1- 07
Indicator poling
RS2- 07
address
04011210
Setting value
Para-
meter
0
1
2
3
As display (simple)
4
5
6
Comparison + As display (simple)
7
Comparison +Gross (simple)
8
Comparison +Net (simple)
9
Totalised (Accu.) Weight and number of
10
0
Transmit continuous + command mode
1
Auto transmit + command mode
2
Manual transmit + command mode
3
4
MODBUS RTU mode
0
1
2
3
4
5
0
N, 8, 1
No parity, 8 data bits, 1 Stop bit
1
O, 7, 1
Odd parity, 7 data bits, 1 Stop bit
2
E, 7, 1
Even parity, 7 data bits, 1 Stop bit
0
N, 8, 2
No parity, 8 data bits, 2 Stop bit
1
O, 8, 1
Odd parity, 8 data bits, 1 Stop bit
2
E, 8, 1
Even parity, 8 data bits, 1 Stop bit
0
1
2
3
4
0 0 0 0 0 0
00
When set to 0, Indicator addressing is not
99
41
Description
As display
Gross only
Net only
Gross (simple)
Net (simple)
Tare
transactions
Command mode
600
1200
2400
4800
9600
19200
Open
1 time/sec.
2 time/sec.
5 time/sec.
10 time/sec.
0 ⇒
1 ⇒
Negative (Net Wt.)
Weight unstable
(OL)
Overload
used
Default
0
3
2
2
2
0
transmit cont.
000000
Stop transmit
0
ZSME400000003