Configuring Slow Drain - Cisco Nexus 6000 Series Configuration Manual

Nx-os layer 2 guide
Hide thumbs Also See for Nexus 6000 Series:
Table of Contents

Advertisement

Configuring the Fabric Extender
Procedure
Step 1
Step 2
Step 3
This example shows how to configure the uplink distance.
switch# configure terminal
switch(config)# fex 100
switch(config-fex)# hardware N2248PQ uplink-pause-no-drop distance 3000
switch(config-fex)#

Configuring Slow Drain

Procedure
Step 1
Step 2
Step 3
Command or Action
configure terminal
Example:
switch# configure terminal
switch(config)#
fex chassis_id
Example:
switch(config)# fex 100
switch(config-fex)#
hardware N2248PQ uplink-pause-no-drop
distance distance-value
Example:
switch(config-fex)# hardware N2248PQ
uplink-pause-no-drop distance 3000
Command or Action
switch# configure terminal
switch(config)# fex chassis_id
switch(config-fex)# hardware fex
slow-port-error-disable-time val
Cisco Nexus 6000 Series NX-OS Layer 2 Switching Configuration Guide, Release 7.x
Purpose
Enters global configuration mode.
Enters configuration mode for the specified FEX.
The range of the chassis_id value is 100 to 199.
Specifies the no-drop distance between the FEX
and the switch.
The maximum distance is 3000 meters.
The hardware N2248PQ
Note
uplink-pause-no-drop distance command
specifies the default 300 meter cable
length.
Purpose
Enters global configuration mode.
Enters configuration mode for the specified FEX.
The range of the chassis_id value is 100 to 199.
Specifies the FEX and the time threshold.
The value of fex is the PID of the configured FEX. The
range of val is from 200ms to 1000ms. The default value
is 1000 ms.
Configuring Slow Drain