Mitsubishi QD51-R24 User Manual page 87

Melesec q series
Hide thumbs Also See for QD51-R24:
Table of Contents

Advertisement

3 SPECIFICATIONS
3 - 52
REMARK
1 This is a task that corresponds to the device No. of the device designated by
Y11, Y12 that is turned ON. However, a device No. that does not have "IT
(started by an interrupt from the programmable controller CPU)" set for the
multitask setting is disregarded.
(4) Reset Request Signal (Y1A)
(a)
This is a signal that resets the QD51 (-R24) module only.
Reset is executed after the access enabled time following the Y reset set by
the GX Developer intelligent function module switch.
Reset request
OFF
Y1A
ON
X0E
Operating
POINT
During reset, set up an interlock with the QD51 (-R24) operating status signal (X0E)
so that there will be no access from a sequence program.
ON
OFF
Wait for reset
Resetting
Reset after access enabled time (200/2000 ms)
following the Y reset set by GX Developer.
MELSEC-Q
Operating
3 - 52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd51

Table of Contents