Output (Y) Detailed Explanation - Mitsubishi QD51-R24 User Manual

Melesec q series
Hide thumbs Also See for QD51-R24:
Table of Contents

Advertisement

3 SPECIFICATIONS

3.8.2 Output (Y) detailed explanation

3 - 49
Here, QD51 (-R24) outputs (Y) are explained.
The output No. (Yn) used in this section is the number as viewed from the
programmable controller CPU.
(1) General Output (Y00 to Y10, Y13 to Y18: 23 points)
The general output signals can be used to send ON/OFF data from the
programmable controller CPU to the QD51 (-R24). The programmable controller
CPU can turn ON and OFF by a sequence programs or GX Developer's device
test function, etc.
In the QD51 (-R24), reading of general output ON/OFF data is accomplished by
the special variable B@.
Programmable controller CPU
(2) Start Task No. Designation Signal (Y11, Y12: 2 points)
(a)
These are signals which designate tasks to start by an interrupt from the
programmable controller CPU and there is one point for each task.
(b)
Tasks with "IT (start by an interrupt from the programmable controller CPU)"
set in the multitask setting are subject to the start task No. designation
signal (Y11/Y12).
The device No. for a task for which the multitask setting is not set on "IT" is
treated the same as a general output.
Device No.
Start by an interrupt from the programmable
Y11
Start task No. setting
Y12
(c)
Turn the start task No. designation signal (Y11/Y12) corresponding to the
task you are starting ON. At the time the task start signal (Y19) rises, the
start task No. designation signal (Y11/Y12) thus designated to be turned
ON will be started.
However, if a task that is currently being executed is designated, it is
disregarded.
Y00
Reading by the
B@ command
ON
Multitask Setting
controller CPU
Task No. 1
Task No. 2
MELSEC-Q
QD51(-R24)
&H00
Task
Task
2
1
Other than at left
General Output
(Impossible to start each task)