Option List

System Configuration

No.
Part name
1
Central remote controller
2
Unified ON/OFF controller
3
Schedule timer
Unification adaptor for computerized
4
control
5
Interface adaptor for SkyAir-series
6
Central control adaptor kit
7
Wiring adaptor for other air-conditioner
DIII-NET
8
Expander adaptor
9
Mounting plate
Note:
Installation box for
Building management system
No.
Part name
1
basic
Hardware
1-1
Hardware
Option
1-2
Software
1-3
1-4
Electrical box with earth terminal (4blocks)
Number of
intelligent Manager
2
units to be
ECO 21
connected
2-1
Optional DIII Ai unit
3
2 Interface for use in BACnet
3-1
Optional DIII board
3-2
Optional Di board
4
3 Interface for use in L
5
Basic unit
Temperature
6
measurement units
7
Temperature setting units
Unification adaptor for computerized
8
control
Wiring adaptor for electrical
9-1
appendices (1)
Wiring adaptor for electrical
9-2
appendices (2)
External control adaptor for outdoor
13
unit (Must be installed on indoor units.)
310
Model No.
Up to 64 groups of indoor units (128 units)can be connected, and ON/OFF, temperature
DCS302C61
setting and monitoring can be accomplished individually or simultaneously. Connectable up
to "2" controllers in one system.
Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or
DCS301B61
simultaneously, and operation and malfunction can be displayed. Can be used in
combination with up to 8 controllers.
Programmed time weekly schedule can be controlled by unified control for up to 64 groups
DST301B61
of indoor units (128 units). Can turn units ON/OFF twice per day.
DCS302A52
Interface between the central monitoring board and central control units
DTA102A52
Adaptors required to connect products other than those of the VRV System to the high-
speed DIII-NET communication system adopted for the VRV System.
DTA107A55
To use any of the above optional controllers, an appropriate adaptor must be installed on
the product unit to be controlled.
DTA103A51
Up to 1,024 units can be centrally controlled in 64 different groups.
DTA109A51
Wiring restrictions (max. length : 1,000m, total wiring length : 2,000m, max. number of
branches : 16) apply to each adaptor.
KRP4A92
Fixing plate for DTA109A51
adaptor must be procured on site.
Model No.
intelligent
Touch
DCS601C51
Controller
DIII-NET
plus
DCS601A52
adaptor
P.P.D.
DCS002C51
Web
DCS004A51
KJB411A
128 units
DAM602A52
192 units
DAM602A53
256 units
DAM602A51
512 units
DAM602A51x2
768 units
DAM602A51x3
1024 units DAM602A51x4
DAM101A51
®
DMS502A51
DAM411A1
DAM412A1
W
DMS504B51
ON
ORKS
DPF201A51
DPF201A52
DPF201A53
DCS302A52
KRP2A53, 61, 62 Simultaneously controls air-conditioning control computer and up to 64 groups of
KRP4A51-54
DTA104A53, 61,
62
Notes:
1. PPD does not support Connection Unit Series.
®
2. BACnet
is a registered trademark of American Society of Heating, Refrigerating and
Air-Conditioning Engineers (ASHRAE).
ORKS 
3. L
W
is a registered trade mark of Echelon Corporation.
ON
Function
• Air-Conditioning management system that can be controlled by a
compact all-in-one unit.
• Additional 64 groups (10 outdoor units) is possible.
• P.P.D.: Power Proportional Distribution function
• Monitors and controls the air conditioning system using the Internet
and Web browser application on a PC.
• Wall embedded switch box.
Air conditioner management system (featuring minimized engineering)
that can be controlled by personal computers.
Analog input for "sliding temperature" function (to reduce cold shock) for
intelligent Manager EC021.
Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through BACnet
communications.
Expansion kit, installed on DMS502A51, to provide 3 more DIII-NET
communication ports. Not usable independently.
Expansion kit, installed on DMS502A51, to provide 16 more wattmeter
pulse input points. Not usable independently.
Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through
L
W
communication.
ON
ORKS
Enables ON/OFF command, operation and display of malfunction; can be used
in combination with up to 4 units.
Enables temperature measurement output for 4 groups; 0-5VDC.
Enables temperature setting input for 16 groups; 0-5VDC.
Interface between the central monitoring board and central control units
indoor units.
To control the group of indoor units collectively, which are connected by the
transmission wiring of remote controller.
Cooling/Heating mode change over. Demand control and Low noise control are
available between the plural outdoor units.
Si39-407
Function
Appendix
®