Vacuum Motor Carbon Brushes - Windsor Clipper Duo Operating Instructions Manual

1.008-048.0 clpdu
Hide thumbs Also See for Clipper Duo:
Table of Contents

Advertisement

Maintenance

Vacuum Motor Carbon Brushes

Carbon Brushes
The green ground wire must be attached for safe
operation. See wiring diagram.
Le fil de mise à la terre vert doit être fixé pour
assurer un fonctionnement sécuritaire. Voir le
schéma de câblage.
If armature commutator is grooved, extremely pitted or
not concentric, the motor will need to be replaced or
sent to a qualified service center.
30
Important:
These brushes wear quicker as the length shortens due
to increased heat. Spring inside brush housing will
damage motor if brushes are allowed to wear away
End Cap
completely.
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less than
3/8" (9.5mm) long.
86408790 Operator's Manual - Clipper Duo
3
8 [9.5mm]