9
BC10 basic controller
9.1.1

Switching the heating system on and off

Switching on the heating system
a
▶ Set the main switch
on the BC10 basic controller to position "1"
(On).
Switching off the heating system
b
▶ Set the main switch
on the BC10 basic controller to position "0"
(Off).
9.1.2
Displaying the operating conditions of the burner and
resetting the burner or resetting burner faults
Displaying the operating conditions of the burner
The LED g indicates the operating condition of the burner.
LED
Condition
Explanation
On
Burner operational The water in the boiler is being heated.
Off
Burner off
The water in the boiler has reached the
required temperature or there is no heat
request.
Table 6 LED indication
The following status displays can be seen depending on the operating conditions:
Displays (examples) Values
[1/4/0|
1)
number 0 ... 199
[p/2/1|
p
> P15
[-/h/\|
q
[p/1/2|
1)
P3 ... P12
[h/\/7|
(changing)
[-/h/\|
p
[1/4/0|
p
number 0 ... 199
[p/1/2|
q
P3 ... P12
[p/3/\|
1)
< P3
(flashing)
[2/0/7|
p
number > 200
[1/4/0|
p
number 0 ... 199
[p/3/\|
q
< P3
[3/a/\|
1)
(partially
Combination of letters
flashing)
and digits
[2/0/7|
p
number > 199
[1/4/0|
p
number 0 ... 199
[p/2/1|
q
> P15
Table 7 Possible status displays
26
Meaning
2)
Current boiler water temperature (in °F)
Current system pressure (in psi)
Warning:
System pressure is too low (between 3 and
12 psi = 0.2 and 0.8 bar)
2)
Current boiler water temperature (in °F)
Current system pressure (in psi)
Fault: system pressure is far too low (< 3 psi =
< 0.2 bar)
Error code
Remedy the error see servicing section
2)
Current boiler water temperature (in °F)
Current system pressure (in psi)
Service code
Error code
Remedy the error using the servicing section
in this manual
2)
Current boiler water temperature (in °F)
Current system pressure (in psi)
Logamax plus GB142-24/30/45/60 – 6720820104 (2017/05)
Resetting the boiler or resetting faults
If the boiler is down due to a fault, you can reset the boiler by pressing
c
the "Reset"
button. This is only possible for so-called lock-out faults.
There is another type of fault, so-called blocking faults, that reset
themselves when the cause has been remedied.
c
▶ Press the "Reset"
button to reset the boiler.
The display shows "rE" [\/r/e| while resetting. It is only possible to reset
the boiler when a lock-out code (blinking fault code) is visible in the
display.
NOTICE:
▶ If the burner returns to fault mode after resetting the
boiler, you must resolve the fault using the servicing
section in this document. Contact your supplier if
necessary.
9.1.3

Displaying the heating system status and/or faults

The display of the BC10 basic controller shows the status of the heating
system.
In the event of a fault the display immediately shows the fault or the
warning in the form of an error code ( section 13.2). The status
display will flash if the fault is a lock-out fault.
e
▶ Press the "Service"
button to switch between status displays or
to read out the service and error codes.
▶ Resolve the fault  section 13.3.
Operating condition/Remedy
Normal operating conditions
Warning
Heating system remains operational between 12 psi
and 3 psi (0.8 and 0.2 bar).
▶ Fill the heating system and restore the minimum
filling pressure (≥ 14.5 psi = ≥ 1.0 bar).
The system pressure is shown for 10 minutes after
which the standard display returns.
Fault
Burner and boiler circuit pump are not operational.
Frost protection is active up to 2 psi (0.1 bar).
The heating system will only become operational again
if the pressure is back to 14.5 psi (1.0 bar).
▶ Fill the heating system and restore the minimum
filling pressure (≥ 14.5 psi = ≥ 1.0 bar).
The system pressure is shown for 10 minutes after
which the standard display returns.
Fault
Lock-out faults (flashing display) must be reset by
pressing the "Reset"
Blocking faults reset automatically as soon as the cause
has been removed.
Remedy any blocking faults that remain active for a
long time using the service section in this manual.
c
button.