Disconnect The Connections On The Burner; Disconnect The Connections On The Pump Head - Kärcher HDS 5/11 U Service Manual

Hide thumbs Also See for HDS 5/11 U:
Table of Contents

Advertisement

1 Fuel line to burner
2 Fuel line from the fuel pump

5.9.3 Disconnect the connections on the burner

Set up the appliance.
Unlock the holding clip of the temperature sensor
with a tool, without damaging the temperature
sensor and remove it from the exhaust stack.
Remove the temperature sensor and carefully un-
thread the capillaries from the back wall.
1 Exhaust nozzle, on-demand heater
2 Temperature sensor
3 Retaining clip
4 Capillary exhaust temperature monitor
Unlock the protective conductor on the burner cov-
er and remove it from the back wall.
Disconnect the cable from the ignition transformer.
24
English 5.906-487.0 Rev. 00 (04/10)
5.9.4 Disconnect the connections on the pump
head
Pull the detergent hose off of the pump head.
1 Detergent hose
2 Pump head
Slightly raise the pump kit.
Unscrew locking screws.
Remove the safety block.
1 Pump set
2 Fastening screw (2x)
3 Safety block

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hds 5/11 ux

Table of Contents