ADJUSTMENT AND CONFIRMATION PROCEDURES 1

Idling current adjustment
Before Idling current adjustment, turn the trimming resistors R6040 to R6046 to counter-clockwise.
Connect the DC voltmeter at the sockets P6080 to P6086.
After turn POWER to ON, adjust the trimming resistors R6040, R6041 and R6042 so that the reading of
voltmeter becomes 11 mV. (Front and center channels)
Adjust the trimming resistors R6043, R6044, R6045 and R6046 so that the reading of
voltmeter becomes 4.5 mV. (Surround and surround back channels)
After adjustment, attach the top cover.
Confirm the voltage of points above after about five minutes.
Front and center channels
When less than 16.5 mV, readjust the resistors above so that the voltage becomes 16.5 mV.
When 16.5 mV to 18.5 mV, you are not necessary to adjust.
When more than 18.5 mV, readjust the resistors above so that the voltage becomes 18.5 mV.
Surround and surround back channels
When less than 6.0 mV, readjust the resistors above so that the voltage becomes 6.0 mV.
When 6.0 mV to 8.0 mV, you are not necessary to adjust.
When more than 6.0 mV, readjust the resistors above so that the voltage becomes 8.0 mV.
Note: No load and No signal
P5004A
P6013
ID+
ID-
P6083
Confirmation of protection circuit
1. Confirmation of operation of speaker relay
Confirm that the speaker relays turn ON approximate. 5 seconds after the power switch is turned ON.
Confirm that the speaker relays turn OFF immediately after the power switch is turned OFF.
2. Confirmation of DC detection circuit
Press and hold down CD button, then press STANDBY/ON and DISPLAY buttons to set the unit to
"Test " mode.
After "Test " on the FL tube light on, press VIDEO 1 button to set the unit to "Test-1-00".
Apply DC 1.5 to 3.5V to the MULTI-CH INPUT terminal with no load.
Confirm that the speaker relay turns OFF.
Apply DC -1.5 to -3.5 V to the MULTI-CH INPUT terminal with no load.
Confirm that the speaker relay turns OFF.
Caution: Don't apply DC voltage more than 1 sec..
P6080
R6040
ID-
ID+
P5003A
P6205
P5004B
P6004
P6003
P6015
BIAS
BIAS
ID+
ID+
ID-
ID-
R6044
P6085
R6043
P6084
P6081
R6042
R6041
ID-
ID+
P6011
P6002
P5003C
P5003B
P5004C
P5004D
P6005
P6016
BIAS
ID+
BIAS
ID-
R6046
R6045
P6086
NCAF-7706
DTR-7.4
ID-
ID+
P6012