DIP Switch Setting

3-1

DIP Switch Setting

Connector Cover Removal
Switch Cover
Setting
Mode Selector Switch
12
The communications interface is set by the DIP switches on the ID Controller. To
gain access to the DIP switches, remove the cover on the monitor unit connec-
tor. Set the DIP switches in accordance with the communication specifications of
the host computer.
Slide the connector cover upward. Insert the tip of a flat-blade screwdriver into
the notch at the right of the cover and remove the cover.
DIP switch 1
DIP switch 2
When the switch cover is opened, a mode selector switch and two DIP switches,
1 and 2, are visible.
The ID Controller operates as follows depending on the mode selector switch
setting.
Settings
Mode
0
RUN
1
2
3
4
TEST
5
6
7
Used by manufacturer for repairs.
8 and 9
Inhibited
Note Do not set switches 7 through 9 during normal operation.
The Mode is set to "0" when the unit is delivered.
Mode selector switch
Operation
Operates as specified by command from host controller.
Although the IC Controller operates in the same manner
regardless of where the selector switch is set (positions 0
through 3), set the switch to position 0.
Continuously reads 1 byte from address 0000 (read test).
Continuously writes 1 byte from address 0000 (write test).
RESERVED
Section
3-1
DIP switch 1
DIP switch 2