The Cause And Solution Of The Malfunction - Samsung ML-2150 Service Manual

Hide thumbs Also See for ML-2150:
Table of Contents

Advertisement

7.3 The cause and solution of the malfunction

7.3.1 Fuser Error
• Description
A message "Open fuser/Over heat/Low heat' is displayed in a LCD panel.
Check and Cause
1. Check whether a thermostat, AC wire, and heat
lamp are open or not.
2. Check whether a thermistor is open or not.
3. Heat lamp ON/OFF test
4. It could not operate due to a gear of a fuser is
melted.
7.3.2 LSU Error
• Description
A message "PMOTOR ERROR/HSYNC ERROR' is displayed in a LCD panel.
Check and Cause
1. Check whether the LSU connector is disconnected or
not.
2. Check whether the LSU motor is rotating or not.
3. Check the HSYNC signal.
Samsung Electronics
Solution
1. Replace the fuser if a thermostat is open.
2. Replace the fuser if a thermistor sensor is
located deep inside of a sponge.
3. Check whether the overheat mode circuit
operates normally or not.
4. Replace the fuser.
Solution
- Replace a LSU
- Replace a main board if the same error occurs again
after replacing a LSU.
T RO U B L E S H O OT I N G
Service Manual
7-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml-2152wMl-2151n

Table of Contents