Emerson Oxymitter 5000 Instruction Manual page 35

Oxygen transmitter with foundation fieldbus communications
Hide thumbs Also See for Oxymitter 5000:
Table of Contents

Advertisement

Oxymitter 5000
Signals:
Digital Output .......................................................
Logic I/O ..............................................................
Power Requirements:
Probe Heater .......................................................
Electronics ...........................................................
Maximum .............................................................
SPS 4000
Mounting ....................................................................
Materials of Construction:
Manifold/Electronics Enclosure ...........................
Mounting Brackets ..............................................
Pneumatic Fittings ...............................................
Pneumatic Tubing ...............................................
Assembly Hardware ............................................
Humidity Range .........................................................
Ambient Temperature Range ....................................
Electrical Classification ..............................................
Explosion-Proof Option (both pending) .....................
Electrical Feedthroughs .............................................
Input Power ................................................................
Power Consumption ..................................................
External Electrical Noise ............................................
Handshake Signal
to/from Oxymitter 5000 (self-powered) ...............
Cal Initiate Contact Input from Control Room ............
Relay Outputs to Control Room .................................
Cabling Distance between
SPS 4000 and Oxymitter 5000 ............................
Piping Distance between SPS 4000
and Oxymitter 5000 .............................................
Approximate Shipping Weight ...................................
Fisher-Rosemount has satisfied all obligations coming from the European legislation to harmonize
the product requirements in Europe.
Rosemount Analytical Inc.
A Division of Emerson Process Management
Table 1-1. Specifications (Continued)
F
OUNDATION
Two-terminal logic contact configurable as either an
alarm output or as a bi-directional calibration hand-
shake signal to IMPS 4000 or SPS 4000
Self-powered (+5 V), in series with 340 ohms
Conduit ports — 3/4 in.-14 NPT (one threaded hole for
both analog output and logic I/O)
175 W nominal
10 W nominal
500 W
Integral to Oxymitter 5000
Remote from Oxymitter 5000
Aluminum
316 stainless steel (SS)
1/8 in. brass NPT (SS optional)
1/4 in. Teflon (SS optional)
Galvanized and stainless steel
100% relative humidity
-40° to 149°F (-40° to 65°C)
NEMA 4X (IP56)
CENELEC EExd IIB + H2
(Class 1, Div. 1, Group B,C,D)
1/2 in. NPT
90 to 250 VAC, 50/60 Hz
5 VA maximum
EN 50 082-2, includes 4 KV electrostatic discharge
5 V (5 mA maximum)
5 VDC (self-powered)
5 to 30 VDC, Form A (SPST)
(one "In-Cal", one "Cal Failed")
Maximum 1000 ft (303 m)
Maximum 300 ft (91 m)
10 lbs (4.5 kg)
Instruction Manual
IB-106-350 Rev. 1.2
fieldbus compatible
Description and Specifications
April 2001
1
1-9