Alarm Condition
Open Thermocouple
Shorted Thermocouple
Reversed Thermocouple
Heater Open Circuit
High High Heater Temperature
High Case Temperature
Low Heater Temperature
High Heater Temperature
Open Cell Circuit
High AC Impedance / Cell Bad
EEPROM Parameters Corrupt
Calibration Recommended
Invalid Slope Value
Invalid Cell Constant Value
Bad Calibration
In Calibration
During Warm Up
The status of channel 1 is affected by the state of the unit alarm, as shown in Table A-5. In
all cases, the channel will read what it believes is the correct oxygen value. Self-clearing
alarms are reset when the alarm condition goes away. All others require the Oxymitter 5000
to be restarted.
Table A-5. Channel 1 Status
Channel 1 Status
Bad
Bad
Bad
Bad
Bad
Bad
Bad
Bad
Bad
Uncertain
Bad
Good
Uncertain
Uncertain
Uncertain
Uncertain
Bad
IB-106-350
A-6
Self-clearing?
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes