Table of commands for ASM 456

Table of commands of the ASM 456 with standard addressing (FB 45)
The assignment is made in UDT 20/UDT 30 using the "command" variable.
Table 5- 4
*) Chained commands are not supported by all readers. Please note the relevant information
in the RFID/MOBY system manuals.
38
ASM 456 commands with normal addressing
Command code
normal
chained*
01
41
02
42
03
43
04
44
08
48
0A
4A
0B
4B
Description
Write to transponder
Read transponder; read fixed code
Initialize transponder
Reader status
Turn off transponder
Switch antenna on/off
Transponder status
Operating Instructions, 07/2015, J31069-D0162-U001-A6-7618
available in
the MOBY system
all
all
RF300 /
RF620R/RF630R /
MOBY U / D
RF200 / RF300 /
RF620R/RF630R /
MOBY U / D
MOBY U
RF200 / RF300 /
RF620R/RF630R /
MOBY U / D
RF200 / RF300 /
RF620R/RF630R /
MOBY U