Usage Condition; Main Function; Operation Mode Indication; Timer - Westinghouse WPAXH-060CA4 Service Manual

R-410a; 220volts 60hz
Table of Contents

Advertisement

WESTINGHOUSE PACKAGE A/C MANUAL
2. Summarize

Usage condition:

. Power supply: 5V DC.
1
. Operation temperature: -15℃-+43℃.
2
. Operation humidity: 40%-90%, RH.
3
3. Function summary

Main function:

. Connecting to indoor unit by A, B, C, D, E terminal;
1
. Button setting action mode.
2
. LCD display.
3
. Timer for rest time.
4
4. Name and fuction of indica tors on the controller

① Operation mode indication:

When press "MODE" button, the following mode can be selected in circle. Auto→Cool →Dry→Heat→Fan
only→Auto. For cooling only model,heat mode is skipped.

② Timer :

When adjust setting on time or only on time is set, the "ON" is lighted.
When adjust setting off time or only off time is set, the "OFF" is lighted. If both 'on' and 'off' timer are set, both
the "ON" and "OFF" are lighted.
③ Follow me function:
There is a temperature sensor inside the wired controller, after setting temperature, it will compare the two
temperatures, and the space of wired controller will be
the same as setting temperature. It is available under cooling, heating, auto mode.
④ ON/OFF indication :
When it is on, the icon display, otherwise it is extinguished.
⑤ Fan speed indication :
There are four fan modes: low, middle, high and auto. For some models, no middle fan then the middle fan is
seen as high speed.
⑥ Lock:
When the "LOCK" button is pressed, the icon appear and other buttons is unable, press again, the icon
disappear.
⑦ Temperature display zone:
Generally it displays setting temperature, it can be adjusted by press temperature button ▲ and ▼. But for
fan mode, no display is here.
R-410A : 220V: 60Hz
99

Hide quick links:

Advertisement

Table of Contents