Superior TF18NE Installation And Operation Instructions Manual page 39

Unvented (vent-free) gas log heaters
Table of Contents

Advertisement

WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.
OBSERVED PROBLEM
Appliance produces unwanted
odors
Appliance shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room tem-
perature drops to a lower than ideal
level before log set comes back on
126818-01C
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Appliance burning vapors from
paint, hair spray, glues, cleaners,
chemicals, new carpet, etc. (See
IMPORTANT statement above)
2. Low fuel supply (propane/LP only)
3. Gas leak. See Warning state-
ment at top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning state-
ment at top of page
2. Control valve or gas control defec-
tive
1. Foreign matter between control
valve and burner
2. Gas leak. See Warning state-
ment at top of page
1. Optional Hand-held remote con-
trol is too close to appliance
SuperiorFireplaces.US.com
REMEDY
1. Open window to ventilate room.
Stop using odor causing products
while appliance is running
2. Refill supply tank (propane/LP
only)
3. Locate and correct all leaks (see
Checking Gas Connections, Page
14)
1. Open window and/or door for
ventilation
2. Contact local natural or propane/
LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, Page 31)
1. Locate and correct all leaks (see
Checking Gas Connections, Page
14)
2. Replace control valve or gas
control
1. Take apart gas tubing and remove
foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections, Page
14)
1. Move hand-held remote control
unit farther away from the appli-
ance
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tf18peTf2430neTf2430pe

Table of Contents