5.7.1 Updating from Ready Mode
Application Version 2.091 (or greater) Update Procedure
Step
Displayed Message
READY
1
2
UPGRADING SOFTWARE
4214
3
11.05 03/26/2008
READY
4
Action
Using the DOS copy
command (where
"filename" is the program
to be loaded and "lpt1" is
the selected interface
port), enter the
following:
copy filename lpt1:
No action required.
No action required.
No action required.
Comment(s)
As an example, this would
be entered as:
copy i4212_1105.zg lpt1
(Where "lpt1" can differ to
include another port, as
equipped.)
The Ready Indicator will
flash as data is received.
The new application is being
stored and verified.
The printer has reset and is
displaying the new firmware
version.
The new application is
running.
Note: If UNCALIBRATED
is displayed, see Section 5.2.