Clearances From Boiler - Rinnai E60SRN Installation & Service Instructions Manual

Table of Contents

Advertisement

5.3.1
ceiling
service clearances to the boiler
Minimum required clearances
Top of boiler
Back of boiler
Front of boiler
Left side of boiler
Right side of boiler
Floor / Ground to
bottom of boiler
Vent
clearances to the boiler
For closet installation: clearance is 1" / 25mm from the front.

Clearances from boiler

Min. 10" /
250mm
15.7"
24"
400
600
to combustibles
All types
inch / mm
0"
0"
1" / 25
0"
0"
0"
0"
2"
50
Minimum required clearances
to non-combustibles
All types
inch / mm
0"
0"
1" / 25
0"
0"
0"
0"
2"
50
figure 4
Required
service clearances
All types
inch / mm
10" / 250
0"
24" / 600
2" / 50
2" / 50
10" / 250
30" / 762
is recommended
0"
table 3
13