User information manual
High efficiency condensing gas boiler
Q85SN/Q130SN/Q175SN/Q205SN/Q175CN
Q85SP/Q130SP/Q175SP/Q205SP/Q175CP
WARNING!
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do NOT try to light any appliance.
- Do NOT touch any electrical switch.
- Do NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call the fire
department.
Address: 103 International Drive, Peachtree City, GA, 30269
Toll-free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Notice! This manual must be retained for future reference.
WARNING!
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Pictured: Q85SN, Q130SN
Q85SP, Q130SP
Français: voir page 17

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai Q130SN

  • Page 1 Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. Address: 103 International Drive, Peachtree City, GA, 30269 Toll-free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us Notice! This manual must be retained for future reference. WARNING! Installation and service must be performed by a qualified installer, service agency or the gas supplier.
  • Page 2 Contents of instructions These instructions contain important information for the safe use of Rinnai Q-Series gas boilers. These user instructions are intended for the owner or responsible tenant of the premises where the boiler is installed. Subject to technical changes Changes may be made to the illustrations, process steps and technical data as a result of our policy of continuous improvement without prior notice.
  • Page 3: Safety And General Instructions

    NOTICE Please observe these instructions in the interest of your own safety. The boiler is designed to heat water for a central heating system and, if applicable, generating domestic hot water. The boiler is delivered with a burner controller pre-installed.The boiler can...
  • Page 4 These operating instructions operation of the Rinnai Q-Series condensing gas boilers. This manual is for the end user. For installation and servicing there is a installation & servicing instructions manual for the installer. Read this manual fully before operating the boiler.
  • Page 5: For Your Safety Read Before Operating

    Safety FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner.
  • Page 6: Checking The Water Pressure

    New building construction Remodeling areas Garages with workshops Checking the water pressure Check the water pressure in the central heating installation regularly. Use only potable water for filling. Additives only after clearance by Rinnai. Contact your installer in case of doubt.
  • Page 7: Description Of The Boiler

    Description of the boiler The Rinnai Q boiler is a room sealed, condensing and modulating central heating boiler. The Q175C has an integrated domestic hot water feature. The boiler is provided with a integrated control system. Because an outdoor sensor is connected to the boiler, the boiler works weather dependantly.
  • Page 8: Explanation Of The Function Buttons

    NOTICE Only qualified personel who are trained for these boilers are permitted to make alterations in the controller to chronolize the boiler to the installation. 1. Display. See following pages for further information. 2. ON-OFF Switch This switch turns the power supply to the boiler on or off.
  • Page 9 When a fault occurs it will be shown by the flashing E (Error) with a number code after which the boiler is shut down. After pressing the reset key you can try to start the boiler again. If the error message keeps occurring contact your installer.
  • Page 10: The Boiler Display

    The second way is a technical read out. In normal situations the following will be shown: • on the left the status in which the boiler is active (see bottom of this page); • on the right the supply temperature in °F;...
  • Page 11: Water Pressure In The Central Heating System

    When the water pressure drops below 10 PSI, the display will show a flashing FILL text. The boiler will shut down and will function normally again after replenishing the system to just above 22 PSI. To retreive the water pressure on the display from the Good reading: Press the Step key once briefly.
  • Page 12 14 Press the ‘STEP’-button; 15 Be sure that the filling loop is closed. After the automatic de-aeration programm (A xx) is finished the boiler will return to the Good reading or Technical reading. Contact your installer if your installation is not provided with a filling loop.
  • Page 13: Turning The Boiler Off

    It can take a while before all air has disappeared from a filled installation. Especially in the first week noises can be heard which indicate the presence of air. The automatic air vent in the boiler will remove the air, which means the water pressure will reduce during this period and therefore topping up with water will...
  • Page 14: Error, Maintenance And Warranty

    Error, maintenance and warranty NOTICE NOTICE NOTICE NOTICE If a fault is detected the boiler will be blocked. This will be reflected, by an alternate display of Good, with an of Error or a BL of Blocking and a number code.
  • Page 15 Maintenance or changes to the appliance may only NOTICE be carried out by a qualified technician. You can find the warranty conditions in the warranty card which is supplied with the boiler.
  • Page 17 - Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies. Addresse: 103 International Drive, Peachtree City, GA, 30269 Gratuit: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us Avis ! Ce manuel doit être conservé pour consultation ultérieure. AVERTISSEMENT! L'installation et l'entrétien doivent...
  • Page 18 Contenu des instructions Ces instructions contiennent d’importantes informations pour l’utilisation en toute sécurité des chaudières à gaz de la série Rinnai Q. Ces instructions d’utilisation sont destinées au propriétaire ou au responsable locataire des locaux où la chaudière est installée.
  • Page 19: Sécurité Et Instructions Générales

    Sécurité et instructions générales Utilisation prévue Définitions des dangers DANGER AVERTISSEMENT ATTENTION Veuillez observer ces instructions dans l’intérêt de votre propre sécurité. La chaudière est conçue pour chauffer de l’eau pour un circuit de chauffage central et, le cas échéant, pour produire de l’eau chaude domestique. La chaudière est livrée avec un contrôleur de brûleur pré...
  • Page 20 Ces instructions de fonctionnement décrivent le fonctionnement des chaudières à gaz à condensation de la série Rinnai Q. Ce manuel est destiné à l’utilisateur final. Pour l’installation et l’entretien, il existe un manuel d’instructions d’installation et d’entretien pour l’installateur.
  • Page 21: Instructions De Mise En Marche

    Sécurité POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHE AVERTISSEMENT: Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. A.
  • Page 22 Zones de remaniement Garages avec ateliers Vérification de la pression d’eau Vérifiez régulièrement la pression d’eau dans l’installation centrale de chauffage. N’utilisez que de l’eau potable pour le remplissage. Additifs uniquement après autorisation de sécurité de Rinnai. Contactez votre installateur en cas de doute.
  • Page 23: Description De La Chaudière

    Description de la chaudière La chaudière Rinnai Q est une chaudière de chauffage central de pièce scellée à condensation et modulante. La Q175C possède une fonction eau chaude domestique intégrée. La chaudière est équipée d'un système de régulation intégré. Grâce à un capteur extérieur connecté...
  • Page 24: Explication Des Boutons De Fonctions

    Explication des boutons de fonctions REMARQUE REMARQUE Lorsque pompe allumée continu, cela peut provoquer un chauffage non souhaité du circuit de chauffage central pendant l’été Seul du personnel qualifié formé pour ces chaudières est autorisé à effectuer des modifications dans le régulateur pour adapter la chaudière à l’installation. 1. Affichage.
  • Page 25 REMARQUE AVERTISSEMENT En cas de gel, il est possible (lorsqu’il n’existe pas de capteur extérieur connecté) de placer manuellement la pompe de circulation en mode de circulation continue, ce qui réduit le risque de gel des tuyaux (garage, grenier ou autres espaces/ pièces froids) qui sont sensibles au gel.
  • Page 26 L’affichage de la chaudière Deux affichages sur la chaudière, “Good ou Technique” voir ci-dessous. Pas de demande de chaleur Pré/post purge du ventilateur Phase d’allumage Brûleur actif sur chauffage central Brûleur actif sur ECS Contrôle du ventilateur Brûleur arrêté à la demande du thermostat d’ambiance Phase de dépassement de la pompe pour chauffage central Phase de dépassement de la pompe pour eau chaude Brûleur arrêté...
  • Page 27 Pression d’eau dans le circuit de chauffage central Message ' Pression d’eau trop faible' sur votre thermostat RS100. Sur l’affichage du RS100, une faible pression de l’eau peut être indiquée. Pour de plus amples informations, voir le manuel de l’utilisateur correspondant L’installation fonctionne de façon optimale avec une pression d’eau comprise entre 22 et 25 PSI...
  • Page 28 Remplissage du circuit de chauffage central L’installation de chauffage central doit être remplie d’eau potable (à boire). Pour remplir l’installation, il vous faut utiliser la boucle de remplissage selon la procédure suivante : REMARQUE 1 Coupez toutes les fonctions (CC 2 Appuyez brièvement sur le bouton ‘STEP’...
  • Page 29: Arrêt De La Chaudière

    La chaudière ne fonctionnera pas directement. Le programme de désaération automatique d’environ 17 minutes démarre après avoir appuyé sur l’un des trois boutons de programme. L’affichage indique pour le programme de désaération actif et le numéro sur la droite indique la température réelle de l’eau dans la chaudière. Vérifiez régulièrement la pression de l’eau et, si nécessaire, refaites le plein de l’installation.
  • Page 30 Erreur, maintenance et garantie REMARQUE REMARQUE REMARQUE REMARQUE Si une panne est détectée, la chaudière est bloquée. Ceci se reflète par l’affichage alterné de Good, avec un E d’Erreur ou un BL de Blocage et un code numérique. Vous pouvez tenter de réinitialiser la chaudière en appuyant une fois sur la touche Reset.
  • Page 31 REMARQUE Le nettoyage du condensat récupéré et du circuit de rejet doit être effectué périodiquement. Avant de mettre la chaudière en marche après un nettoyage périodique, remplissez le purgeur du condensat avec 1,27 tasse / 300 ml d’eau. Etape 1 : Purgeur de condensat Retirez d’abord la tasse de condensation (7) ;...
  • Page 32 Numéro de téléphone en dehors des horaires d’ouverture : Distributor for the USA and Canada Distributeur pour l'Etats-Unis et Canada Rinnai America Corporate • 103 International Drive • Peachtree City, GA 30269 To l l F r e e :...