Setting Mode
memo
FUNCTION
SETTING
SETTING
EXAMPLE
1, 2, 3...
76

Power Failure Memory

Retains the process value at the time of power failure if the operating mode of the
K3NR is set to F7 (pulse counting).
Setting
on:
Stored
off: Not Stored
Follow the steps described below to set on to enable power failure memory.
1. Press the Mode Key for more than one second while the opt option menu is
displayed. The aUg average processing setting will appear.
2. Repeatedly press the Mode Key until the memo power failure memory setting
is displayed.
3. Press the Shift Key to display the set data off for changing. The PROG indi-
cator will flash.
4. Press the Up Key to display on. The setting will be validated automatically if
no change is made for five seconds. The memo power failure memory setting
will be displayed again.
Note Press the Mode Key to enter the displayed setting immediately. The
next parameter will be displayed for setting.
Default
off
Set Value LED Display Model
Set Value LED Display Model
Set Value LED Display Model
Set Value LED Display Model
Set Value LED Display Model
Section 4-2
Basic Model
Basic Model
Basic Model
Basic Model
Basic Model