Siemens MICROMASTER 440 Operating Instructions Manual page 199

Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 10/03
Input voltage range
(Unfiltered)
Order No.
Output Rating (CT)
Output Power
CT Input Current 1)
CT Output Current
VT Input Current 1)
VT Output Current
Recommended Fuse
Pipe cable shoe to
DIN 46235
Max. wire cross section
Weight
1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
voltage of 400 V without line commutating reactor.
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
6SE6440- 2UD38-8FA1 2UD41-1FA1 2UD41-3GA1 2UD41-6GA1 2UD42-0GA1
[kW]
90
[hp]
125
[kVA]
145.4
[A]
168.5
[A]
178.0
[A]
204.5
[A]
205.0
[A]
250
3NE
1227-0
[mm]
10
1 x 185 or
[mm²]
2 x 120
[AWG]
1 x 350 or
bzw.
2 x 4/0
[kcmil]
[kg]
110
[lbs]
242
≥ 2.33 % referred to the rated drive converter power and a rated line supply
k
5 MICROMASTER 440 specifications
3 AC 380 V – 480 V, ± 10 %
110
132
150
200
180
214.8
204.0
244.5
205.0
250.0
244.5
296.5
250.0
302.0
315
400
1230-0
1332-0
10
10
1 x 185 or
2 x 240
2 x 120
1 x 350 or
2 x 400
2 x 4/0
110
170
242
418
160
200
250
300
263.2
339.4
296.4
354
302.0
370.0
354.0
442.0
370.0
477.0
450
560
1333-0
1435-0
10
10
2 x 240
2 x 240
2 x 400
2 x 400
170
170
418
418