Parameter list
8.2 Parameter list
Parameter
Function
r2817.0
BO: OR 1
Output of OR 1 element. Displays or logic of bits defined in P2816[0], P2816[1]. See r2811 for the bit field
description.
Dependency:
See P2816
P2818[0...1]
BI: OR 2
P2818[0], P2818[1] define inputs of OR 2 element, output is r2819.
Index:
See P2810
Dependency:
P2801[4] assigns the OR element to the processing sequence.
r2819.0
BO: OR 2
Output of OR 2 element. Displays or logic of bits defined in P2818[0], P2818[1]. See r2811 for the bit field
description.
Dependency:
See P2818
P2820[0...1]
BI: OR 3
P2820[0], P2820[1] define inputs of OR 3 element, output is r2821.
Index:
See P2810
Dependency:
P2801[5] assigns the OR element to the processing sequence.
r2821.0
BO: OR 3
Output of OR 3 element. Displays or logic of bits defined in P2820[0], P2820[1]. See r2811 for the bit field
description.
Dependency:
See P2820
P2822[0...1]
BI: XOR 1
P2822[0], P2822[1] define inputs of XOR 1 element, output is r2823.
Index:
See P2810
Dependency:
P2801[6] assigns the XOR element to the processing sequence.
r2823.0
BO: XOR 1
Output of XOR 1 element. Displays exclusive-or logic of bits defined in P2822[0], P2822[1]. See r2811 for the
bit field description.
Dependency:
See P2822
P2824[0...1]
BI: XOR 2
P2824[0], P2824[1] define inputs of XOR 2 element, output is r2825.
Index:
See P2810
Dependency:
P2801[7] assigns the XOR element to the processing sequence.
r2825.0
BO: XOR 2
Output of XOR 2 element. Displays exclusive-or logic of bits defined in P2824[0], P2824[1]. See r2811 for the
bit field description.
Dependency:
See P2824
P2826[0...1]
BI: XOR 3
P2826[0], P2826[1] define inputs of XOR 3 element, output is r2827.
Index:
See P2810
Dependency:
P2801[8] assigns the XOR element to the processing sequence.
300
Range
Factory
default
-
-
0 - 4294967295
0
-
-
0 - 4294967295
0
-
-
0 - 4294967295
0
-
-
0 - 4294967295
0
-
-
0 - 4294967295
0
Can be
Scaling
changed
-
-
U, T
-
-
-
U, T
-
-
-
U, T
-
-
-
U, T
-
-
-
U, T
-
Operating Instructions, 11/2016, A5E34559884-006
Data
Data
Acc.
set
type
Level
-
U16
3
-
U32
3
-
U16
3
-
U32
3
-
U16
3
-
U32
3
-
U16
3
-
U32
3
-
U16
3
-
U32
3