SPN = Suspect Parameter Number
ASPN = Alternate Suspect Parameter Number
FMI = Failure Mode Identifier
SPN
ASPN FMI
Description
24035 65283 12
Injector diagnostics; time out error in the SPI communication
24036 65284 12
Injector diagnostics Slave; time out error in the SPI communication
24037 65285 3
Ashlamp; short circuit to battery
4
Ashlamp; short circuit to ground
5
Ashlamp; open load
24038 65286 9
Timeout error of CAN-Receive-Frame ComMS_Sys1TO (error memory Slave); Master-Slave
internal CAN message
24039 65287 9
Timeout error of CAN-Receive-Frame ComMS_Sys2TO (error memory Slave); Master-Slave
internal CAN message
24040 65288 9
Timeout error of CAN-Receive-Frame ComMS_Sys3TO (error memory Slave); Master-Slave
internal CAN message
24041 65289 9
Timeout error of CAN-Receive-Frame ComMS_Sys4TO (error memory Slave); Master-Slave
internal CAN message
24042 65290 9
Timeout error of CAN-Receive-Frame ComMS_Sys5TO (error memory Slave); Master-Slave
internal CAN message
24043 65291 9
Timeout error of CAN-Receive-Frame ComMS_Sys6TO (error memory Slave); Master-Slave
internal CAN message
24044 65292 9
CAN message ComMS_Sys7 not received from slave
24045 65293 9
Master-Slave CAN; Message-Counter-Error of CAN-Receive-Frame ComMSMoFOvR
24046 65294 9
Master-Slave CAN; Checksum-Error of CAN-Receive-Frame ComMSMoFOvR
24047 65295 9
Master-Slave CAN; Messsage-Length-Error of CAN-Receive-Frame ComMSMoFOvR
24048 65296 9
Timeout error CAN message ComMSMoFOvR1TO error memory Slave
24049 65297 9
Message copy error in the Master / Slave data transfer
24052 65300 11
MS ECU reported internal error
24055 65303 4
Spark Plug Control Unit (SPCU); short circuit to ground
24057 65305 2
Electric fuel pump; fuel pressure build up error
24062 65310 12
EAT-system HMI disrupted
24063
3
SCR main relay; short circuit to battery
4
SCR heater main relay load side (K31 on heating valve (Y31)
5
SCR heater return line; open load or SCR main relay not connected; or SCR heater
pressureline; open load or SCR or SCR relay for suction line not connected or SCR heater
supply module; open load or SCR heater tank; open loac
12
DEF supply module, time for defrosting too long or DEF tank, time for defrosting too long
Part No. 1278145