Troubleshooting - Monessen Hearth AVFL42NTSC Installation & Operating Instructions Manual

Avfl vent free fireplace system
Table of Contents

Advertisement

AVFL Vent Free Fireplace
Turn appliance OFF and allow to cool
before servicing.
Only a qualified service person should
service and repair the heater.
PROBLEM
Appliance produces unwanted odors.
Appliance shuts off during use.
Gas odor even when control knob is in
OFF position.
Burner does not light after ODS/pilot is lit.
Burner backfires during combustion.
Slight smoke or odor combustion.
Logs appear to smoke after initial
operation.
Heater produces a whistling noise when
burner is lit.
No gas to pilot.
Monessen • AVFL42 Installation Instructions • 20305467 Rev. B • 02/17
34
NOTE: All troubleshooting items are listed in order of op-
eration.
POSSIBLE CAUSE
Appliance burning vapors from paint, hair
spray, glues, etc.
Gas leak.
Initial burn off.
Not enough fresh air is available for
ODS/pilot to operate.
Low line pressure.
ODS/pilot is partially clogged.
Defective thermopile.
Gas leak
Control valve defective.
Burner orifice is clogged.
Burner orifice diameter is too small.
Inlet gas pressure is too low.
Manifold gas pressure is too low.
Burner orifice is clogged.
Burner orifice is clogged or damaged.
Burner is damaged.
Gas regulator defective.
Vapor from paint or curing process of
logs.
Air in gas line.
Dirty of partially clogged burner orifices.
LP regulator shut down due to inlet
pressure too high.

TROUBLESHOOTING

SOLUTION
Ventilate room. Stop using odor causing
products while heater is running.
Locate and correct all leaks.
Ventilate room and turn unit on high until
odor is gone. Odor should be gone after
six hours of continuous use.
Open window and/or door for ventilation.
Contact local gas company.
Clean ODS/pilot.
Check wire connections. Check
output should be 500 millivolts across
thermopile leads with ON/OFF switches
off.
Locate and correct all leaks.
Replace control valve.
Burner orifice is clogged.
Burner orifice diameter is too small.
Inlet gas pressure is too low.
Contact local gas company.
Clean burner or replace burner orifice.
Clean burner or replace burner orifice.
Replace burner.
Replace gas regulator.
Problem will stop after a few hours
of operation. Run the heater with the
damper open if you have one, or open a
window for the first few hours.
Log heater is intended to be smokeless.
Turn OFF heater and call qualified
service person.
Operate burner until air is removed from
line. Have gas line checked by local gas
company.
Clean burner or replace burner orifice.
Verify LP tank regulator is installed and
set at 11" to 13" w.c.
Replace regulator on heater.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avfl42ptsc

Table of Contents