9 Settings
Configuration
Contact type H1
NC | NO
Voltage value 1 H1
Function value 1 H1
Voltage value 2 H1
Function value 2 H1
Function input H4
None | Optg mode change CHs+HW | Optg mode changeover HW | Optg mode
changeover CHs | Optg mode changeover CH1 | Optg mode changeover CH2 |
Optg mode changeover CH3 | Heat generation lock | Error/alarm message |
Consumer request VK1 | Consumer request VK2 | Release swimpool source
htg | Excess heat discharge | Release swi pool solar | Operating level HW |
Operating level CH1 | Operating level CH2 | Operating level CH3 | Room
thermostat CH1 | Room thermostat CH2 | Room thermostat CH3 | Hot water
thermostat | Pulse count | Checkb sign flue gas damper | Start prevention | Flow
measurement Hz
Contact type H4
NC | NO
Frequency value 1 H4
Function value 1 H4
Frequency value 2 H4
Function value 2 H4
Function input H5
None | Optg mode change CHs+HW | Optg mode changeover HW | Optg mode
changeover CHs | Optg mode changeover CH1 | Optg mode changeover CH2 |
Optg mode changeover CH3 | Heat generation lock | Error/alarm message |
Consumer request VK1 | Consumer request VK2 | Release swimpool source
htg | Excess heat discharge | Release swi pool solar | Operating level HW |
Operating level CH1 | Operating level CH2 | Operating level CH3 | Room
thermostat CH1 | Room thermostat CH2 | Room thermostat CH3 | Hot water
thermostat | Pulse count | Checkb sign flue gas damper
Contact type H5
NC | NO
Function output P1
None | Boiler pump Q1 | Hot water pump Q3 | HW interm circ pump Q33 |
heating pump CH1 Q2 | heating pump CH2 Q6 | heating pump CH3 Q20 |
Collector pump Q5 | Solar pump ext exch K9 | Solar pump buffer K8 | Solar
pump swi pool K18
Sensor type collector
NTC | Pt 1000
Readjustm collector sensor
Readjustm outside sensor
Time constant building
Central setp compensation
System frost protection
Off | On
Save sensors
No | Yes
Reset to default parameters
Check no. heat source 1
Check no. heat source 2
Check no. storage tank
Check no. heating circuits
Software version
68
Paramount four 30 – 115 kW
Prog. no.
Level
Standard value
5951
C
NO
5953
E
0
5954
E
0
5955
E
10
5956
E
100
5970
C
None
5971
C
NO
5973
E
0
5974
E
0
5975
E
0
5976
E
0
5977
C
None
5978
C
NO
6085
E
heating pump CH1
Q2Boiler pump Q1
6097
E
NTC
6098
E
0 °C
6100
E
0.0 °C
6110
C
10 h
6117
E
10 °C
6120
E
On
6200
C
No
6205
C
No
6212
E
6213
E
6215
E
6217
E
6220
E
7658013 - 02 - 15092016