Selecting Power Supply Units - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

Cabinet design and EMC for components, Blocksize format
10.5 24 V DC Supply Voltage
10.5.5

Selecting power supply units

You are advised to use the devices in the following table. These devices meet the applicable
requirements of EN 60204-1.
Table 10- 4
Recommended SITOP Power
Rated output
Phases
current [A]
5
1 / 2
10
1 / 2
20
1 / 2
3
40
1 / 2
3
Table 10- 5
Recommendation for Control Supply Module
Rated output
current [A]
20
3
Refer also to Catalog PM21 or NC61.
Danger to life through a hazardous voltage when connecting an unsuitable power supply
Touching live components can result in death or severe injury.
• Connect the ground potential to the protective conductor connection.
• Mount the power supply close to the drive lineup.
426
Rated input voltage [V]
Operating voltage range [V]
AC 120 ... 230 / 230 ... 500
85 ... 264 / 176 ... 550
AC 120 ... 230 / 230 ... 500
85 ... 264 / 176 ... 550
AC 120 / 230
85 ... 132 / 176 ... 264
3 AC 230 / 400 ... 288 / 500
320 ... 550
AC 120 / 230
85 ... 132 / 176 ... 264
3 AC 230 / 400 ... 288 / 500
320 ... 550
Input voltage range [V]
380 V 3 AC -10 % (-15 % < 1
min) to 480 V 3 AC +10%
DC 300 ... 800
WARNING
Ideally, they should be mounted on a common mounting plate. If different mounting
plates are used, their electrical interconnection must comply with the EMC installation
guideline.
Short-circuit current [A]
Approx. 5.5 (power up)
Typ. 15 for 25 ms
(operation)
Approx. 12 (power up)
Typ. 30 for 25 ms
(operation)
Approx. 23 (power up)
Typ. 60 for 25 ms
(operation)
Approx. 46 (power up)
Typ. 120 for 25 ms
(operation)
Short-circuit current [A]
< 24
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Order number
6EP1333-3BA00-8AC0
6EP1334-3BA00-8AB0
6EP1336-3BA00-8AA0
6EP1436-3BA00-8AA0
6EP1337-3BA00-8AA0
6EP1437-3BA00-8AA0
Order number
6SL3100-1DE22-0AAx
AC Drive

Advertisement

Table of Contents
loading

Table of Contents