Samsung AR**HS Installation Manual page 9

Table of Contents

Advertisement

Left
Left
<Possible directions of the pipe bundle>
CAUTION
• If changing the pipe direction from left to right, do not
drastically bent it but slowly turn it in the opposite
direction as shown. Otherwise, the pipe may be
damaged in the process.
<Minimum distances between the hole and the
installation plate>
Model
36
09/12
8 English
A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 8
Right
Rear right or left
Bottom right
Pipe bundle hole
(Unit : mm)
A
B
C
D
147
81
36
Pipe bundle hole: Ø 65 mm
Drill the hole.
2
CAUTION
• Be sure to drill only one hole.
• Make sure that the hole slants downwards so that the
drain hose slants downwards to drain water well.
Indoor unit
<The hole slants downwards>
Step 1.4 Taping the pipes, cables, and
drain hose
1
Wrap foam insulation on parts without insulation on
the ends of the refrigerant pipes, as shown in the
figure. This wrapping minimises condensation problem.
Insulation
Refrigerant pipes
2
Wind the refrigerant pipes, power cable,
communication cable and drain hose with vinyl tape to
make a pipe bundle.
Installation plate
Vinyl tape
Power and communication cables
(assembly cable)
Drain hose
Wall
Drain hose
Refrigerant pipes
(assembly pipe)
2016/4/20 14:10:17