Summary of Contents for Samsung AR**HS

  • Page 1 AR • Tha • Bef refe A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 32 2016/4/20 14:10:13...
  • Page 2: Air Conditioner

    Air conditioner Installation manual ARHS/JS • Thank you for purchasing this Samsung air conditioner. • Before operating this unit, please read this Installation manual carefully and retain it for future reference. A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 1 2016/4/20 14:10:13...
  • Page 3: Table Of Contents

    Step 4.1 Performing the gas leak tests Step 4.2 Running the Smart Install mode Step 4.3 Performing final check and trial operation Sub PCB installation(optional) For information on Samsung’s environmental commitments and product specific regulatory obligations e.g. REACH visit: samsung.com/uk/aboutsamsung/samsungelectronics/ corporatecitizenship/data_corner.html 2 English A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 2...
  • Page 4: Installation

    • This manual explains how to install an indoor unit the electrical lines. Always disassemble the electric with a split system with two SAMSUNG units. The use lines before the refrigerant tubes. of other types of units with different control systems may damage the units and invalidate the warranty.
  • Page 5 trucks, scaffolding or any other means of elevation Power supply line, fuse, or circuit won’t be considered in-warranty and will be charged breaker to end user. • Always make sure that the power supply is compliant • When installing the outdoor unit at the seaside, make with current safety standards.
  • Page 6: Preparation

    Preparation Step 1.1 Choosing the installation CAUTION location • Comply with the length and height limits described in the figure above. If using a multi system, install as described in the installation manual supplied with the outdoor unit. Minimum clearances for the outdoor unit Overview of installation location requirements Wall 100 mm or more...
  • Page 7: Step 1.2 Checking And Preparing Accessories And Tools

    When installing more than 1 outdoor unit Step 1.2 Checking and preparing (5 cases) accessories and tools (Unit: mm) Accessories Accessories in the indoor unit package 1500 3000 3000 Installation plate (1) Remote control (1) Remote control battery (2) User Manual (1) Smart A/C application Manual Installation Manual (1) Cap screw (2)
  • Page 8 If using a multi system, refer to the manual supplied NOTE with the outdoor unit. • A flare nut is attached to the end of each pipe of an evaporator or a service port. Use flare nuts when connecting the pipes. Optional accessories • Wire assembly cables are optional.
  • Page 9 Drill the hole. CAUTION Left Right Left • Be sure to drill only one hole. • Make sure that the hole slants downwards so that the Rear right or left drain hose slants downwards to drain water well. Bottom right Wall <Possible directions of the pipe bundle>...
  • Page 10: Indoor Unit Installation

    Indoor Unit Installation Please scan this QR code for detail video of indoor unit installation. Step 2.1 Disassembling the cover panel Remove the cap screws, then the screws. Cap screw Screw Step 2.2 Disassembling the Phillips screwdriver Flat-head screwdriver installation plate Unlock the side hooks ( , ), then centre hooks ( ).
  • Page 11: Step 2.3 Connecting The Power And Communication Cables (Assembly Cable)

    Step 2.3 Connecting the power and • When performing electrical and earthing works, be sure to comply with the 'technical standards of communication cables (assembly electrical installations' and the 'wiring regulations' in cable) the local regulations. • Tighten the terminal block screw to 1.2-1.8 N•m (12- If using a multi system, install as described in the 18 kgf•cm).
  • Page 12: Step 2.4 Optional: Extending The Power Cable

    Step 2.4 Optional: Extending the Using a compressor, compress the two points and flip it over and compress another two points in the same power cable location. • The compression dimension should be 8.0. Prepare a compressor and the following tools. Tools Spec Shape...
  • Page 13: Step 2.5 Installing And Connecting The Drain Hose

    WARNING CAUTION • In case of extending the electric wire, please DO NOT • Make sure that the indoor unit is in upright position use a round-shaped pressing socket. when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical –...
  • Page 14: Step 2.7 Optional: Changing The Direction Of The Drain Hose

    Step 2.7 Optional: Changing the Step 2.8 Installing and connecting direction of the drain hose the assembly pipes to the refrigerant pipes (assembly pipe) Connect indoor and outdoor units with field-supplied Drain pan outlet copper pipes by means of flare connections. Use insulated Rubber cap seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable...
  • Page 15: Step 2.9 Shortening Or Extending The Refrigerant Pipes (Assembly Pipe)

    Remove the protection caps of the pipes and connect Step 2.9 Shortening or extending the the assembly pipe to each pipe. Tighten the nuts first refrigerant pipes (assembly pipe) with your hands, and then with a torque wrench, applying the following torque: Pipe cutter Outer diameter (mm) Torque (N•m)
  • Page 16: Step 2.10 Fixing The Installation Plate

    Step 2.10 Fixing the installation plate CAUTION You can install the indoor unit on a wall, window frame, or • If you need a pipe longer than specified in piping gypsum board. codes and standards, you must add refrigerant to the pipe.
  • Page 17: Step 2.11 Fixing The Indoor Unit To The Installation Plate

    Attach the installation plate to the wooden upright using tapping screws. When fixing the indoor unit on a gypsum board Use stud finder to find out locations of the studs. Fix the plate hanger on two studs. CAUTION • If you fix the indoor unit on a gypsum board, use only specified anchor bolts on reference positions.
  • Page 18: Outdoor Unit Installation

    Outdoor Unit Installation Optional: Fixing the outdoor unit to a wall with If using a multi system, install as described in the a rack installation manual supplied with the outdoor unit. Soft rubber designed to cut off vibration from Step 3.1 Fixing the outdoor unit in rack to wall (not supplied with product) place Rubber leg...
  • Page 19: Step 3.3 Evacuating The Air

    Leave the system in the standby mode. WARNING • Do not turn on the system! This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve). Control box Remove the screw for the Connect the charging hose of the low pressure side control box cover of manifold gauge to a gas service port as seen in the picture.
  • Page 20: Step 3.4 Adding Refrigerant

    Step 3.4 Adding refrigerant Step 3.5 Important information regulation regarding the refrigerant If you use a pipe longer than the length specified in used the piping codes and standards, you must add 15g of refrigerant R-410A for each extra metre. If you use a pipe This product contains fluorinated greenhouse gases.
  • Page 21 NOTE Factory refrigerant charge of the product: see unit name plate Additional refrigerant amount charged in the field (Refer to the above information for the quantity of refrigerant replenishment.) Total refrigerant charge Refrigerant cylinder and manifold for charging CAUTION • The filled-out label must be adhered in the proximity of the product charging port (e.g.
  • Page 22: Installation Inspection

    Installation Inspection Step 4.1 Performing the gas leak tests Before inspecting the leakage, use a torque wrench to close the cap for the stop valve. (Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.) Test parts for the indoor unit Tightening torque for body...
  • Page 23 When error occurs, take necessary measures by referring to the following table. For more information on necessary measures for errors, refer to the service manual. Error indicator LED Display Error Measures for the installer to take LED 1 LED 2 LED 3 Display Communication...
  • Page 24: Step 4.3 Performing Final Check And Trial Operation

    Step 4.3 Performing final check and Turn off the air conditioner and switch mains supply off. trial operation Disconnect tubing. After disconnection, protect valves Check the following: and tubing ends from dust. • Strength of the installation site CAUTION • Tightness of pipe connection to detect gas leak • Electric wiring connection • Compressor damage may occur if the compressor is • Heat-resistant insulation of the pipe...
  • Page 25: Sub Pcb Installation(Optional)

    Sub PCB installation(optional) 5 Connect the wire(remote controller, central remote Only for multi system controller etc) to the Sub PCB. 6 Assemble the Cover PCB and the front panel. (Wried remote controller, central remote controller etc.) If the Sub PCB is not installed, arrange the wire for ...