Outdoor Unit Installation

If using a multi system, install as described in the
installation manual supplied with the outdoor unit.
Step 3.1 Fixing the outdoor unit in
place
Rubber leg
Model
09/12
AJ040/050
AJ052/060/070/080
AJ100
1
Place the outdoor unit as directed on the top of the
unit to let the discharged air out properly.
2
Fix the outdoor unit in level to an appropriate support
using anchor bolts.
NOTE
• Secure the rubber legs to help prevent the generation
of noise and vibration.
• If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit so that the fan
can operate correctly.
A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 17
X
(Unit : mm)
X
Y
612
317
660
340
620
360
Optional: Fixing the outdoor unit to a wall with
a rack
Soft rubber designed to cut off vibration from
rack to wall (not supplied with product)
Soft rubber designed to cut off residual vibration
from outdoor unit to rack (not supplied with product)
NOTE
• Make sure that the wall can support the weights of the
rack and the outdoor unit.
• Install the rack close to the column as much as
possible.
Step 3.2 Connecting the power
and communication cables and the

refrigerant pipes

L
N
Outdoor-to-indoor
Power cable
power cable
(three wires)
(three wires)
CAUTION
• Be sure to fix the power cables and communication
cable with a cable clamp.
• Power & Communication cable shall not exceed 30m.
F1
F2
Communication cable
(two wires)
English
17
2016/4/20 14:10:23