Canon i-SENSYS MF229dw Service Manual page 292

Table of Contents

Advertisement

■ SPECIALB
• Not in use
■ SPECIALN
• Not in use
■ RKEY
1) Numeric value parameter
Parameter No.
Function
001
Connection time of flash
002
Connection time of grounding wire
003
■ PBXDIALT
1) Bit switch
Bit No.
Function
Bit 0
Frequency detection method Modem
Bit 1
Bit 2
Signal frequency
Changed
Bit 3
Bit 4
Judgment of intermittent
Start from valid ON
signal
signal
Bit 5
Bit 6
Signal form
Continuous
Bit 7
Signal detection
Detected
2) Numeric value parameter
Parameter No.
Function
001
T0 timer
002
T1 timer
003
T2 timer
004
T3 timer
005
T4 timer
006
Signal detection table
007
Signal detection level
008
Number of valid tone detection
8
Service Mode > FAX > List of NCU > PBXBUSYT
Setting range
0 to 9999 (x10ms)
0 to 9999 (x10ms)
T-8-43
1
0
Tonal counter
Not changed
Start from either valid
ON signal or OFF signal
Intermittent
Not detected
T-8-44
Setting range
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 16
0 to 9
0 to 9999 (times)
T-8-45
8
Service Mode > FAX > List of NCU > PBXBUSYT
■ PBXBUSYT
1) Bit switch
Bit No.
Function
Bit 0
Bit 1
Bit 2
Signal frequency
Bit 3
Bit 4
Judgment of intermittent
signal
Bit 5
Bit 6
Signal form
Bit 7
Signal detection
2) Numeric value parameter
Parameter No.
Function
001
-
T1 timer
002
T2 timer
003
T3 timer
004
T4 timer
005
Signal detection table
006
Signal detection level
007
Number of valid tone detection
008
8-19
1
0
Changed
Not changed
Start from valid ON
Start from either valid
signal
ON signal or OFF signal
Continuous
Intermittent
Detected
Not detected
T-8-46
Setting range
-
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 9999 (x10ms)
0 to 16
0 to 9
0 to 9999 (times)
T-8-47