Disassembly/Assembly > Original Exposure/Feed System (SADF Model) > Removing the Flat Bed Motor Unit (SADF Model) > Procedure
3) Remove the Guide Cover [1].
• 1 Claw [2]
1x
[2]
4) Free the harness [1] and the Grounding Wire [2] from the hole [A] of the Reader Unit and
the Harness Guide [B].
1x
[B]
[1]
[2]
4
Disassembly/Assembly > Original Exposure/Feed System (SADF Model) > Removing the Flat Bed Motor Unit (SADF Model) > Procedure
[1]
F-4-182
[A]
F-4-183
5) Remove the Flat Bed Motor Unit [1].
• 2 Screws [2]
2x
[2]
CAUTION:
If the Contact Image Sensor Unit comes off, be sure to put the tooth [1] of the belt in the
groove [2] on the bottom of the Contact Image Sensor to install the unit.
[2]
[1]
4-74
[2]
[1]
F-4-184