4
Disassembly/Assembly > Pickup Feed System (Simplex Model) > Removing the Pickup Solenoid (Simplex Model) > Procedure
6) Free the Pickup Solenoid Harness [1] from the Harness Guide [A].
[A]
7) Move the Solenoid Arm [1] to remove the Pickup Solenoid [2].
• 1 Screw [3]
1x
[1]
[3]
4
Disassembly/Assembly > Pickup Feed System (Simplex Model) > Removing the Pickup Solenoid (Simplex Model) > Procedure
[A]
[1]
1x
F-4-568
[2]
F-4-569
NOTE:
The following shows how to route the harness.
4-192
F-4-570