Disassembly/Assembly > Controller System (Duplex Model) > Removing the Fixing Delivery/Paper Width Sensor PCB (Duplex Model) > Procedure
5) Free the harness [1] from the Harness Guide [A].
• 1 Terminal [2]
1x
1x
[2]
CAUTION:
Be sure that the terminal [2] is in contact with the Contact Spring [3].
[2]
[3]
4
Disassembly/Assembly > Controller System (Duplex Model) > Removing the Fixing Delivery/Paper Width Sensor PCB (Duplex Model) > Procedure
6) Remove the Harness Retaining Spring [1] from the 2 hooks [2].
[1]
[A]
7) Disconnect the 4 connectors [1].
F-4-315
[2]
[3]
F-4-316
[2]
[1]
4x
[1]
4-113
F-4-317
F-4-318
4-113