DATABASE (4)

To troubleshoot and correct the cause of the alarm, refer to the
HeartBeat: Replication PUSH Job Broken—Database (4)" section on page
DESCRIPTION
Element Management System Database HeartBeat: Replication PUSH Job Broken (EMS
DB_Heart_Beat: Replication PUSH Job Broken)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Host Name–STRING [30]
Local Database–STRING [10]
Remote Database–STRING [10]
Job–STRING [5]
Time Stamp–STRING [20]
PRIMARY
The remote database is not accessible.
CAUSE
PRIMARY
Re-start up or restore the remote database.
ACTION
SECONDARY
The remote database is down.
CAUSE
SECONDARY
Restart the remote listener process.
ACTION
TERNARY
The remote Oracle listener process has died.
CAUSE
TERNARY
Correct the network connection problem.
ACTION
SUBSEQUENT
The network connection is broken.
CAUSE