Chapter 4
Call Processing Troubleshooting

CALLP (34)

To monitor and correct the cause of the event, refer to the
Received—Call Processing (34)" section on page
DESCRIPTION
Dial Plan Information Not Found for Digits Received
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Calling Number–STRING [20]
Called Number–STRING [20]
Dial Plan Index–FOUR_BYTES
PRIMARY
The call could not be completed because the number entered could not be located in the dial-plan.
CAUSE
PRIMARY
Check the provisioning and the number dialed.
ACTION
CALLP (35)
To monitor and correct the cause of the event, refer to the
Found—Call Processing (35)" section on page
DESCRIPTION
Dial Plan Information for Test Call Not Found
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Dial Plan Index–FOUR_BYTES
PRIMARY
The test call could not be completed because the number entered could not be located in the dial-plan.
CAUSE
PRIMARY
Check the provisioning and the number tested.