Table 28. Error event IDs and error codes (continued)
Event
Notification
ID
type
Condition
073007
W
There are fewer Fibre Channel ports operational than are
configured.
073305
W
One or more Fibre Channel ports are running at a speed
that is lower than the last saved speed.
073310
E
A duplicate Fibre Channel frame has been detected,
which indicates that there is an issue with the Fibre
Channel fabric. Other Fibre Channel errors might also be
generated.
073501
E
Incorrect canister position.
073502
E
No enclosure identity; cannot get status from partner.
073503
E
Incorrect enclosure type.
073504
E
No enclosure identity and partner does match.
073505
E
No enclosure identity and partner does not match.
073506
E
No enclosure identity and no state on partner.
073507
E
No enclosure identity and no node state.
073508
W
Clustered system identity is different on the enclosure
and the node.
073509
E
Cannot read enclosure identity.
073510
E
Detected memory size does not match the expected
memory size.
073512
E
Enclosure VPD is inconsistent
073522
E
The system board service processor has failed.
073523
W
The internal disk file system of the node is damaged.
073525
E
Unable to update the service processor firmware of the
system board.
073528
E
Ambient temperature is too high during system startup.
073535
E
The internal PCIe switch of the node canister failed.
073550
E
Cannot form clustered system due to lack of resources.
073556
E
Duplicate WWNN detected on the SAN.
073562
E
The node hardware does not meet the minimum
requirements.
073565
E
The internal drive of the node is failing.
073573
E
The node software is inconsistent.
073574
E
The clustered system data cannot be read.
073578
E
The clustered system data was not saved when power
was lost.
073651
E
The canister battery is missing.
073652
E
The canister battery has failed.
073653
E
The canister battery's temperature is too low.
073654
E
The canister battery's temperature is too high
073655
E
The canister battery communications fault.
073656
E
The canister battery has insufficient charge.
Error
code
1061
1065
1203
1192
1192
1192
1192
1192
1192
1192
1023
1036
1032
1008
1034
1187
1034
1098
1034
1192
1133
1034
1032
1187
1187
1194
1153
1154
1156
1157
1158
1184
Chapter 9. Event reporting