136
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Table 28. Error event IDs and error codes (continued)
Event
Notification
ID
type
Condition
062001
W
Unable to mirror medium error during volume copy
synchronization
062002
W
The mirrored volume is offline because the data cannot
be synchronized.
062003
W
The repair process for the mirrored disk has stopped
because there is a difference between the copies.
070000
E
Unrecognized node error.
070510
E
Detected memory size does not match the expected
memory size.
070517
E
The WWNN that is stored on the service controller and
the WWNN that is stored on the drive do not match.
070521
E
Unable to detect any Fibre Channel adapter.
070522
E
The system board processor has failed.
070523
W
The internal disk file system of the node is damaged.
070524
E
Unable to update BIOS settings.
070525
E
Unable to update the service processor firmware for the
system board.
070528
W
The ambient temperature is too high while the system is
starting.
070550
E
Cannot form clustered system due to lack of resources.
070556
E
Duplicate WWNN detected on the SAN.
070558
E
A node is unable to communicate with other nodes.
070562
E
The node hardware does not meet minimum
requirements.
070564
E
Too many software failures.
070574
E
The node software is damaged.
070576
E
The clustered system data cannot be read.
070578
E
The clustered system data was not saved when power
was lost.
070580
E
Unable to read the service controller ID.
070690
W
Node held in service state.
071820
W
Node canister has the incorrect model for the enclosure.
071840
W
Detected hardware is not a valid configuration.
071841
W
Detected hardware needs activation.
072900
E
There was a PCIe link failure between canisters.
072901
E
The PCIe link is degraded between canisters.
072911
E
The PCIe link for the CPU is degraded.
073003
E
The Fibre Channel ports are not operational.
073005
E
Clustered system path failure.
073006
W
The SAN is not correctly zoned. As a result, more than
512 ports on the SAN have logged into one Storwize
V7000 port.
Error
code
1950
1870
1600
1083
1022
1192
1016
1020
1187
1027
1020
1182
1192
1192
1192
1183
1188
1187
1030
1194
1044
1189
3020
1198
1199
1006
1052
1034
1060
1550
1800

Advertisement