1. HOW TO INSTALL THE EQUIPMENT
1.5

Input/Output Data List

This unit uses the following input/output data
Input/
Output
Input
ISO request (PGN: 059904)
Address claim (PGN: 060928)
Self Test Group Function (PGN: 061184)
Memory Clear Group Function (PGN: 126720)
Reset Group Function (PGN: 126720)
NMEA-Request Group Function (PGN: 126208)
NMEA-Command Group Function (PGN: 126208)
+ (PGN: 130818, #4)
+ (PGN: 065283, #4, #5, #6, #7)
Output
Vessel Heading (PGN: 127250)*1
Magnetic Compass Status (PGN: 065284)*2
ISO Acknowledgement (PGN: 059392)
ISO Request (PGN: 059904)
Address Claim (PGN: 060928)
NMEA Acknowledge (PGN: 126208)
PGN List (PGN: 126464)
Product Information (PGN: 126996)
Self Test Report (PGN: 130816)*2
Heading & Attitude Sensor Control Status (PGN:
130818)*2
Unit Division Code (PGN: 130822)*2
Browser Control Status (PGN: 130823)*2
Magnetic Compass Control Status (PGN: 065283)*2
Rate Gyro Data (PGN: 065285) *1*2
GMM Message (PGN: 126720, #4=4)*2
PGN: Parameter Group Number. Equivalent to NMEA0183 sentence.
*1: Data can be output at an interval of 25ms and over (5ms steps) according to the request from
another device.
*2: PGN registered to Furuno Electric Co. Ltd.
Specification
12
Remark
PGN send request
Address request
Self test request
Corresponding to clear all
Corresponding to reset all
Output period setting
Change setting
Input bearing adjustment
Specific setting
Regular output.
100 ms (default)
1sec.
Irregular output. (Send only
when there is a request during
startup and changes). Dis-
plays each setting.