Lamp Status Display - Furuno PG-700 Operator's Manual

Integrated heading sensor
Table of Contents

Advertisement

3. MAINTENANCE AND TROUBLESHOOTING
3.2

Lamp status display

Lamp Status
CALIB
STATUS
CALIB
STATUS
CALIB
STATUS
CALIB
STATUS
CALIB
STATUS
Light alternately.
CALIB
STATUS
Light alternately.
CALIB
STATUS
: ON (green)
Normal state
• Deviation correction: success
CHECK
• Angular velocity sensor: initialization complete
• Deviation correction: success
• Angular velocity sensor: initializing
CHECK
• Deviation correction: not implemented (or failed)
CHECK
• Angular velocity sensor: initialization complete
• Deviation correction: not implemented (or failed)
CHECK
• Angular velocity sensor: initializing
• Deviation correction: success
• Angular velocity sensor: failure
CHECK
• Heading data output of the magnetic sensor only
• Deviation correction: not implemented (or failure)
CHECK
• Angular velocity sensor: failure
• Heading data output of the magnetic sensor only
• Magnetic bearing sensor: failure
CHECK
• No output of magnetic bearing data
: ON (red)
Unit operating condition
: OFF
16
: Flashing (green)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents