Powering Down the Server

The server does not completely power down when the power button on the front panel is pressed. The
button toggles between On and Standby. The standby position removes power from most electronics
and the drives, but some internal circuitry remains active. To completely remove all power from the
system, disconnect all power cords from the server.
To power down the server:
1.
Shut down server as directed by the operating system documentation.
2.
Press the power button to toggle to Standby.
This places the server in standby mode changing the power LED indicator to amber. In this
mode, the main power supply output is disabled. Standby does not completely disable or
remove power from the system.
3.
Disconnect the AC power cord from the AC outlet and then from the server.
4.
Be sure that the power LED indicator is turned off and that the fan noise has stopped.
5.
Disconnect all external peripheral devices from the server.

System Covers

The top cover is detachable for system fans and AC power board maintenance. If you need to repair
or replace a server component, it's unnecessary to remove the top cover.

Top Cover

To remove the top cover:
1.
Remove the screws securing the top cover to the chassis.
2.
Slide the top cover and then lift them away from the chassis.
These symbols, on power supplies or systems, indicate that the equipment is supplied
by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords
to completely disconnect power from the system.