CHECKING FLOW
SETTING : After initialize Agilent 8960, Test EGSM900, DCS mode ( or GSM850, PCS mode )
Check microphone sound hole
Make a phone call,
then check TP1 mic bias signal
comes from U100?
YES
Check the signal
Level at each side of TP4.
Is it a few tens mV AC?
YES
Check the soldering of
YES
Microphone will work

LGE Internal Use Only

START
NO
TP2/TP3
properly.
NO
1. Check mic Bias signal line
2. Change the U100
Change the microphone
NO
Resolder component
- 104 -