Dürkopp Adler 512 Assembly Instructions Manual page 58

Hide thumbs Also See for 512:
Table of Contents

Advertisement

Error message Description
E
5
0 3
SUM read error
E
5
0 4
Endblock error
E
5
0 5
USB read error
E
5
0 6
USB read error
E
5
0 7
Own seam
appearances
read error
E
5
0 8
Own seam
appearances file
error
E
5
0 9
Own seam
appearances file
error
E
5
1 0
Own seam
appearances file
error
E
5
1 1
USB write error
E
5
1 2
USB read error
E
5
1 3
USB write error
E
5
5 0
Data write error
56
Possible cause
CHECKSUM data in MOT
file faulty
No Endblock in the MOT file • Store the Endblock file
USB stick not found
Reading from U01 ~ U10 not
possible.
Read error U01 ~ U10
Read error U01 ~ U10
Read error U01 ~ U10
Read error U01 ~ U10
File with the same name
already present
Data cannot be loaded from
the USB stick
Data cannot be copied to the
USB stick.
Flash memory transfer error • Main power switch OFF.
Operating Instructions 512/532 - 04.0 - 08/2016
Programming
Remedy
• Store the CHECKSUM
file anew on the USB
stick.
anew on the USB stick.
• Main power switch OFF.
• Main power switch ON.
• Plug in the USB stick
again.
• Main power switch OFF.
• Main power switch ON.
• Plug in the USB stick
again.
• Download data again.
• Check the file type.
• Check the file type.
• Check the file type.
• Store the data anew on
the USB stick.
• Delete or rename the file.
• Check the USB stick.
• Plug in the USB stick
again.
• Check the USB stick.
• Plug in the USB stick
again.
• Repeat the procedure.
• Replace the mainboard.

Advertisement

Table of Contents
loading

This manual is also suitable for:

532

Table of Contents