9.2 Displaying alarms and activating individual components

1. Access the diagnostic mode (see 9.1)
2. Press button Ok/Start to begin displaying alarms:
The display shows the last alarm that has occurred (to decode the alarm, see the table of alarms).
3. Press button Ok/Start once again to display the next to the last alarm that has occurred
4. Press button Ok/Start once again to display the third from the last alarm that has occurred
5. Press button Ok/Start repeatedly to scroll through the electronic components, as shown on the table
below.
(2)
Presses of
button
Ok/Start
1
1 ERR CODE i 0
2
1 ERR CODE i 0
3
1 ERR CODE i 0
4
2 TEST ACTIVAT. 4
5
2 TEST ACTIVAT. 5
6
2 TEST ACTIVAT. 6
7
2 TEST ACTIVAT. 7
8
2 TEST ACTIVAT. 8
9
2 TEST ACTIVAT. 9
10
2 TEST ACTIVAT. 10
11
2 TEST ACTIVAT. 11
2 TEST ACTIVAT. 12
12
Power is supplied to components when the door is closed. If no button is pushed within 60
seconds, the system automatically exits the diagnostic mode.
NB: All functions can be accessed multiple times by pressing button Ok/Start repeatedly.
Display
Displays last alarm that has occurred (for example, no alarm)
Displays the next to the last alarm (for example, no alarm)
Displays the third from the last alarm (for example, no alarm)
Activates regeneration solenoid
Activates drain pump
Activates water fill solenoid until full level is reached
Activates heating (only with water at full level!)
Activates wash pump at 2800 RPM
Cycles detergent/rinse-aid dispenser
Activates drying fan (if turbo-dry)
Activates auto-dosing (currently not used)
Activates water hardness sensor (currently not used)
(4)
Function activated
30