Siemens SINUMERIK 840DE Operation & Programming Manual page 180

Hide thumbs Also See for SINUMERIK 840DE:
Table of Contents

Advertisement

11
Alarms and Messages
11.2 Alarms with ManualTurn
111 400
Explanation
Reaction
Remedy
111 410
Explanation
Reaction
Remedy
111 411
Explanation
Reaction
Remedy
111 420
Explanation
Reaction
Remedy
11-180
Unknown PLC error
An error signal unknown to the user interface has been output by the
PLC.
Alarm display
NC start disable
Activate POWER ON, inform Siemens.
Tool %1 was created
As ManualTurn starts, it check that all standard tools are present. If
any are not, the missing tools are generated automatically.
If more than one tool is created, the tools are output in a combined
message.
Meaning:
%1
Number of tool which was created,
%1
First and last tool which were created,
None
None
%1 tool(s) could not be created
As ManualTurn starts, it check that all standard tools are present. If
any are not, the missing tools are generated automatically.
The specified number of tools could not be created in this case.
Alarm display
NC start disable
Increase machine data 18082 $MM_NUM_TOOL by the specified
amount.
Error at inch/metric switchover!
Check all data!
Data switchover was not fully terminated for inch/metric switchover.
Alarm display
NC start disable
Check the following data:
• Display machine data:
MD9004: $MM_DISPLAY_RESOLUTION
MD9600: $MM_CTM_SIMULATION_DEF_X
MD9601: $MM_CTM_SIMULATION_DEF_Y
MD9602: $MM_CTM_SIMULATION_DEF_VIS_AREA
MD9603: $MM_CTM_SIMULATION_MAX_X
MD9604: $MM_CTM_SIMULATION_MAX_Z
MD9605: $MM_CTM_SIMULATION_MAX_VIS_AREA
MD9616: $MM_CTM_TEACH_HANDW_FEED_P_MIN
© Siemens AG, 2002. All rights reserved
SINUMERIK 840D/810D Operator's Guide ManualTurn (BAM) – 08.02 Edition
11
08.02
Example:
5
5...16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840dSinumerik 810dSinumerik 810de