Access Point Tech Specs References

Access Point Operating Temperature Specifications

Temperature Condition
Operating Temperature Range
Maximum Operating Temperature for
AP1572EC, with:
Maximum Operating Temperature for:
OL-32138-01
PoE-Out active
Cable Modem active
Full throughput on all Tx channels
Mounted horizontally Maximum solar
loading
Deployed in a high-power regulatory domain
AP1572IC, AP1572EAC
AP1572EC without all features active, or
mounted vertically (aids better air flow over
the radiating fins on the back of the AP)
Cisco Aironet 1570 Series Outdoor Access Point Hardware Installation Guide
Access Point Operating Temperature Specifications
Value
-40 to 65°C (-40 to 149°F) with solar loading
45°C (AP will be fully operational with 4Tx)
If temperature continues to increase, the number
of transmitters is decreased to 2Tx, and then to
1Tx at 55°C.
> 45°C
A-3