Chapter 5
Troubleshooting

Monitoring the Power Injector LEDs

You can use the power injector LEDs to check the power injector status. The LEDs provide the following
status information:

Using the Reset Button

The access point has a reset button located on the base (see
the status LEDs. The reset button is recessed in a small hole that is sealed with a screw and a rubber
gasket.

Resetting the Access Point

The Reset button reboots the access point. To use the Reset button:
Step 1
Use a Phillips screwdriver to remove the reset button screw.
Ensure that your do not to lose the screw and the rubber gasket.
Step 2
To press the Reset button, use a straightened paper-clip or a small screwdriver or a pen.
Step 3
Inspect the gasket. If the gasket has any signs of damage, it should be replaced to avoid water leakage
into the unit.
Step 4
Close the recess with the screw and the gasket. Use a Phillips screwdriver to tighten the screw to
1.8 to 2 lb.ft (2.49 to 2.71 Nm).
OL-32138-01
AP POWER—Turns solid green after successful discovery; indicates that power injector is
supplying power to the access point.
FAULT—Turns solid red when a fault occurs during discovery mode or power-up. Check Ethernet
cables and connections before contacting your support organization for assistance.
AC POWER—Turns solid green when power injector is receiving AC power and is ready to provide
power to the access point.