Graco PRO 5500wb Instructions-Parts List Manual page 45

Air spray gun
Table of Contents

Advertisement

Install the Gun onto the Manifold
(continued)
7. To ensure the o-rings (C) on the barbed-fitting are
seated in the gun, loosen the nut (D) and push the
fluid hose into the gun until the barbed-fitting
bottoms out. See Fig. 40.
WARNING
ELECTRIC SHOCK HAZARD
To maintain grounding continuity, the
conductive hose layer (E) must be
engaged in the fitting (P1) when the nut
(D) is tightened. See Fig. 40. Failure to properly
install the hose into the fitting could result in an
electric shock.
8. Tighten the nut (D) firmly with a wrench to about
55 in-lb (6.2 NSm). Pull back on the hose to make
sure it is secure.
CAUTION
If the hose comes loose from the fitting (P1), fluid
leakage will occur. Make sure the nut (D) is tight and
that nothing will pull or catch on the hose during
operation.
2
9
1
12
Fig. 41
Service
Fig. 40
9. Slide the shroud (2) onto the gun (B). See Fig. 41.
10. Carefully install the air cap (12) and gasket (3–not
shown). Do not bend the electrode (13), and be
sure to insert the electrode wire through the center
air cap hole. Rotate the air cap horns to the de-
sired position.
11. Make sure the o-ring (9) is in place on the air cap
retaining nut (1). Tighten the retaining nut until the
air cap (12) is held firmly in place; you should not
be able to rotate the air cap horns by hand.
121
108
105
B
17
21
13
C
Ç Ç Ç Ç Ç
Ç Ç Ç Ç Ç
P1
E
106
D
101
102
A
P1
D
D
05927
E
04321
308496
45

Advertisement

Table of Contents
loading

Table of Contents