Software Release History
The software listed below is used in one of more types Argus relay. The list of software revisions applying to
Argus 1, up to and including this document issue is:
Nov 2005
2434H80023 R10
July 2005
2434H80023 R9
Mar 2005
2434h80023 R8
Aug 2004
2434H80023 R7
April 2004 2434H80023 R6
Jan 2004
2434H80023 R5
Sep 2003
2434H80023 R4
Mar 2003
2434H80023 R3
Nov 2002
2434H80023 R2
Jun 2002
2434H80023 R1
Feb 2002
2434H80022 R3
Oct 2001
2434H80022 R2
Feb 2001
2434H80022 R1
Jan 2000
2434H80021 R5
Jul 1999
2434H80021 R4
May 1999
2434H80021 R3
Mar 1998
2434H80020 R1
Sep 1997
2434H80019 R4
Jul 1997
2434H80019 R3
Apr 1997
2434H80018 R2
Jan 1997
2434H80024...7 R2
Oct 1996
2434H80024...7 R1
Mar 2000
2434H80002...7 R17
Mar 1998
2434H80002...7 R16
Jan 1997
2434H80002...7 R15
©2010 Siemens Protection Devices Limited
Highset and Lowset setting steps revised between 2.5xIn and 3.0xIn
ACD bit in IEC 60870 library corrected
CBF logic modified, timer will run while trip is being issued and I >
ICBF
Modification to "checking settings" screen at switch on. Corrected "CT
Failure"
setting
display
PRIMARY/SECONDARY Amps.
ASDU4 measurands return value 0 correctly.
Minimum setting for P/F – E/F elements now 0.05 xIn
Additional features: Modbus added
Additional features: CT Failure function added
Minor change:
IEC60870 Class 2 measurands
Additional features: CBF Level detectors added
Minor change:
DTL timers extended to 5 minutes
Minor change:
Time synch via IEC870
Minor change:
communications with Reydisp
Minor change:
power on alarm added
Additional features: CB fail (all models).
Additional features: external trip via status input.
Minor change:
SEF 2
Additional features: general alarms, status input inversion, resettable
instruments, output relay pulse length setting, 10
second delay on trip test.
Additional features: CB fail, trip circuit supervision (single-pole
models).
Minor change:
current meter averaging.
Minor change:
status group select
Additional features: default instruments
Additional features: new expansion board (8SI).
Additional features: clock synchronisation using status input
Minor change:
settings displayed in ReyDisp
Additional features: status input pick-up and drop-off delays added.
Additional features: CB fail, trip circuit supervision (all expanded I/O
models).
Minor change:
separate settings for P/F, E/F and SEF current
ratings.
Minor change:
sum of I
Additional features: CB fail, trip circuit supervision (some models).
Additional features: reset of latched output relays by status input.
Minor change:
event numbers.
Additional features: new status input functions: setting group select,
all algorithms can be inhibited.
Additional features: first version with I/O expansion card (4SI+4OR).
Minor change:
current meter averaging.
Minor change:
real time clock.
Minor change:
settings group changes delayed until no
protection elements are operating.