Model Selection / Model Reset ( MDL )
The model selection selects the desired model memory from the 10 model memories stored
within the transmitter, and the model reset erases all data stored in a specific model memory.
Model Selection
T h i s f u n c t i o n p r o v i d e s a
4-character name for each of the
model memories in the transmitter
to easily select the correct setup
for the model currently in use.
• Clearly label each model for easy
selection.
Select the battery alarm voltage
according to the battery to be used.
*The voltage drop of a rechargeable battery
and a dry cell battery is different. When
using a rechargeable battery, always change
the voltage.
●4 dry cell batteries ⇒ 4.2V
●HT5F1800B (5cell NiMH battery) ⇒ 5.0V
●FT2F1700BV2/FT2F2100BV2 (2cell LiFe battery) ⇒ 5.8V
System changes (T-FHSS, S-FHSS,
F H S S , T- F H S S < H i g h - S p e e d > )
matched to the receiver type.
When the system was changed and
when a model of a different system
was selected, signal are output in the
system set at the point at which the
transmitter power was turned back on.
●R314SB/R304SB - T-FHSS (TFH), T-FHSS High-Speed (TFH-HS) : The voltage of the receiver is shown to a transmitter.
●R203GF --- S-FHSS (SFH), FHSS (FH)
When using the T3PV in the T-FHSS High-Speed mode, always use it under the following conditions:
Servos
Receiver's battery :Matched to the ratings of the receiver and connected digital servo (dry cell battery can-
not be used).
Under other conditions, the set will not operate, or the specified performance will not be displayed even if it
operates. In addition, it may cause servo trouble.
16
Model number
(1 - 0)
Selection key
Model name
Model Name ( MDL NAME )
Low Battery Alarm ( LBA )
System Type ( SYS )
:Futaba digital servo (including BLS Series brushless servos)

3PV-2.4G Functions

Model Reset
Push the DT1 lever right or left
for about two seconds.
All data stored in the currently
selected model memory is
erased.
Model Name
Model number
(1 - 0)
Model name
(Selection)
Low battery voltage
System Type
(Selection key)
Alarm start voltage
TFH: T-FHSS
SFH: S-FHSS
FH: FHSS
TFH-HS: T-FHSS <High-Speed>
Power Switch: OFF → ON
Voltage change
System change